Wall cladding

OS - 3x12,5 DFH2IRE/KAP

on a hat profile structure with triple DFH2IR boards. 12.5 mm without mineral wool filling

OS - 3x12,5 DFH2IRE/KAP

Technical data

Fire resistance class
Fire resistance class
EI 60 2) 
Max height
Max height
12.0 m
Wall mass
Wall mass
36 kg/m2
Cladding mass
Cladding mass
37 kg/m2

The above-mentioned parameters apply to a partition made of sheet metal profiles with a thickness of 0.55 and 0.6 mm.

Standard

super impregnowany super

It provides a very stable building with the highest fire resistance, sound insulation and hardness. Increased moisture resistance.

super impregnowany

Wall cladding elements

1
Norgips S plasterboard type DFH2IR , thickness: 12.5 mm
2
Norgips top hat profiles, max. axial spacing every 60 cm 1)
3
Optional Norgips sealing tape, width 75 mm
4
Norgips 3.5 x 25 mm sheet metal screws, max. spacing every 75 cm
5
Norgips 3.5 x 35 mm sheet metal screws, max. spacing every 75 cm
6
Norgips 3.5 x 55 mm sheet metal screws, max. spacing every 25 cm
7
Steel dowels, min. ∅ 6 x 40 mm in two rows every 100 cm
8
Norgips Start & Finish ready-made joint compound or Norgips Start gypsum joint compound
9
Norgips reinforcing tape
10
Ready-made joint compound Norgips Extra Finish, ready-made joint compound Norgips Start & Finish, gypsum joint compound Norgips Finish
Download To file
System datasheet OS - 3x12,5 DFH2IRE/KAP
1)
If profiles are used in the horizontal orientation, their maximum profile axial spacing must be decreased to 500 mm. Moreover, the material consumption must be corrected using the calculator.
2)
Based on classification no. LBO-070-KZ/20
Lining surface area m2
Swpie
Material
Unit
Consumption per 1 m2
Consumption
on {total} m2
Price
per unit*
Value

Value of materials per 1 m2 of wall cladding

:
{get_calculation_per_meter} PLN

Value of materials per 1 m2 of wall cladding

: {get_calculation_per_meter} PLN

Total value of materials for the wall cladding surface area

:
{get_total_calculation} PLN

Total value of materials for the wall cladding surface area

: {get_total_calculation} PLN

The above material consumption standards are just estimates and do not include waste resulting from material installation. The calculation does not constitute a commercial offer within the meaning of Article 66 § 1 of the Civil Code.

* In order to calculate the wall construction cost, enter material unit prices.

Q1 - Double filling of plasterboard joints and connections with a structural joint filler (Norgips Start & Finish or Norgips Star), sealing a reinforcing tape, covering visible fasteners with a joint filler

Q2 - Includes the Q1 scope plus filling plasterboard joints with a finish joint filler (Norgips Extra Finish, Norgips Start & Finish or Norgips Finish) until a smooth transition of a joint into a plasterboard surface is achieved

Q3 - Includes the Q2 scope plus filling the entire partition element (joints and cardboard) with an approx. 1 mm thick layer of finish joint filler (Norgips Extra Finish, Norgips Start & Finish or Norgips Finish) to level the surface, close all pores and consolidate absorptivity of filled surfaces

Project information:
Additional comments:
Save the prepared calculation:
PDF calculator OS - 3x12,5 DFH2IRE/KAP
XLS calculator OS - 3x12,5 DFH2IRE/KAP

Download To file
Declaration of Performance Declaration of Performance No. Acoustic Super 12,5/N/2025 date: 13 Aug 2025 – DFH2IRE 12,5 - EN 520

Download To file
Technical sheet KT - Sheet metal screws
Download To file
Technical sheet KT - Sheet metal screws consumer packed
Download To file
Technical sheet KT - NORGIPS Extra Finish
Download To file
Technical sheet KT - Rawlplugs, consumer packed
Download To file
Technical sheet KT - Hat profile made of 0.6 mm sheet metal
Download To file
Technical sheet KT - NORGIPS Finish MEGA
Download To file
Technical sheet KT - Rawlplugs
Download To file
Technical sheet KT - Fleece tape 50 mm
Download To file
Technical sheet KT - NORGIPS Start & Finish
Download To file
Technical sheet KT - Sound insulating sealing tape
Download To file
Technical sheet KT - Paper tape 50 mm
Download To file
Technical sheet KT - Sheet metal screws on a strip 3,5 x 25 mm - EN
Download To file
Technical sheet KT - NORGIPS Finish
Download To file
Technical sheet KT - NORGIPS Start
Download To file
Technical sheet KT - NORGIPS S ACOUSTIC SUPER 12.5 mm type DFH2IRE

Download To file
Catalogues and leaflets NORGIPS solutions - Shaft walls & wall linings
Acoustic adaptation made from NORGIPS Super Acoustic plasterboards
Increasing the acoustic insulation of the wall - stages of acoustic adaptation made from NORGIPS ACOUSTIC type A plasterboards
Installation of NORGIPS wall lining system on hat profiles, with a single-layer plasterboard cladding - assembly steps
Installation of NORGIPS wall lining system on CD60 profiles, with a single-layer plasterboard cladding - assembly steps
NORGIPS Tips: Bathroom shelf made of drywall materials
Hat profile made of 0.6 mm sheet metal
Top hat profile (structural profile)
Sheet metal screws on a strip 3,5 x 25 mm New
Phosphate-coated sheet metal screws for affixing plasterboards to steel profiles
Sheet metal screws on a strip 3,5 x 35 mm New
Phosphate-coated sheet metal screws for affixing plasterboards to steel profiles
Sheet metal screws 3.5 x 25 mm
Phosphate-coated sheet metal screws for affixing plasterboards to steel profiles
Sheet metal screws 3.5 x 35 mm
Phosphate-coated sheet metal screws for affixing plasterboards to steel profiles
Sheet metal screws 3.5 x 55 mm
Phosphate-coated sheet metal screws for affixing plasterboards to steel profiles
Sheet metal screws consumer packed 3.5 x 25 mm
Phosphate-coated sheet metal screws for affixing plasterboards to steel profiles
Sheet metal screws consumer packed 3.5 x 35 mm
Phosphate-coated sheet metal screws for affixing plasterboards to steel profiles
Sheet metal screws consumer packed 3.5 x 55 mm
Phosphate-coated sheet metal screws for affixing plasterboards to steel profiles
Rawlplugs 6 x 40 mm
Rawlplugs for fixing profiles
Rawlplugs, consumer packed 6 x 40 mm
Rawlplugs for fixing profiles
Fleece tape 50 mm
Fleece tape for reinforcing plasterboard joints
Paper tape 50 mm
Paper tape for reinforcing plasterboard joints
Sound insulating sealing tape 75 mm
Self-adhesive tape for perimeter sealing in plasterboard lining systems
NORGIPS Finish MEGA New
Ready-mixed finishing compound for smooth pointing and skimming of indoor mineral substra…
NORGIPS Start & Finish
Ready-mixed dual-purpose filler and finishing compound for grouting plasterboard joints a…
NORGIPS Extra Finish
Ready-mixed finishing compound for grouting plasterboard joints and thin-layer levelling …
NORGIPS Start
Gypsum filler for grouting plasterboard joints
NORGIPS Finish
Gypsum filler for grouting plasterboard joints and thin-layer levelling of mineral substr…
Send a message

We believe that personal data security is a very important issue.
As a result, we provide you with information about the personal data we process. The personal data Controller is Norgips Sp. z o.o. with its registered office /02-255/ Warszawa, ul. Krakowiaków 50. Your data will be processed for the purpose of handling the inquiry you sent to us.
Find more in our Privacy Policy.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Rafał Kaczmarczyk
Deputy Technical Support Manager
Document file
Document file
close

A selection of downloads and material consumption calculations from our website can be included in the document folder.

Click

'To folder' on any document or calculation.

With the document folder you can easily prepare documentation for your investment including:

  • technical documentation of products and solutions
  • material consumption calculations
  • summary product list
  • title sheet with investment metric
Download ZIP Download ZIP
Download PDF Download PDF
Send to @ Send to @
 Clear the file
Close
up