SDM - 2x12,5 GKB A + DFH2IRE/1x12,5 DFH2IRE/2xCW 50 2xW

on a double structure made of CW50 and UW50 profiles, hybrid with double sheathing with GKB type A boards, thickness: 12.5 mm and sheathed three times with type DFH2IR boards , thickness: 12.5 mm with mineral wool filling

SDM - 2x12,5 GKB A + DFH2IRE/1x12,5 DFH2IRE/2xCW 50 2xW

Technical data

Fire resistance class
Fire resistance class
EI 60 (hmax=4.0 m) 1) 2) 
Max height
Max height
4.4 m 1) 
Wall mass
Wall mass
53 kg/m2 3) 
Acoustic insulation
Acoustic insulation
RW=65 dB 4)  RA1=57 dB 4) 

The above-mentioned parameters apply to a partition made of sheet metal profiles with a thickness of 0.55 mm and 0.6 mm or 0.55 mm

Standard

recommended recommended

It provides higher building stability, fire resistance and sound insulation. The optimal solution.

recommended

Partition wall components

1
Norgips S GKB type A plasterboards of 12.5 mm thickness 12.5 mm
2
Norgips S plasterboard type DFH2IR , thickness: 12.5 mm
3
Norgips CW 50 profiles, max. axial spacing every 60 cm
4
Norgips UW 50 profiles mounted on horizontal load-bearing elements
5
Norgips sealing tape, width 50 mm
6
Norgips 3.5 x 25 mm sheet metal screws, max. spacing every 75 cm
7
Norgips 3.5 x 35 mm sheet metal screws, max. spacing every 25 cm
8
Fastening pins, min. ∅ 6 x 40 mm, max. spacing every 80 cm
9
Openings in studs for installation wires
10
Norgips Start & Finish ready-made joint compound or Norgips Start gypsum joint compound
11
Norgips reinforcing tape
12
Ready-made joint compound Norgips Extra Finish, ready-made joint compound Norgips Start & Finish, gypsum joint compound Norgips Finish
13
Mineral wool
Download To file
System datasheet SDM - 2x12,5 GKB A + DFH2IRE/1x12,5 DFH2IRE/2xCW 50 2xW
1)
The stated heights apply to constructions with a profile spacing of 600 mm. When a structure with profiles spaced every 300 or 400 mm is used, the permissible wall height increases. Contact system provider representatives for details. The stated heights apply to rooms where only a few persons are present simultaneously (e.g. rooms in flats, hotels, hospitals). In rooms where a large number of persons are present simultaneously (e.g. conference rooms, classrooms, lecture halls), the permissible height is 3.7 m.
2)

Based on classification no. LBO-127-KZ/24 for 50 mm rock wool

3)
The weight specified does not include the insulation material weight.
4)

Based on report no. A 211002 for 2x50 mm glass wool

Lining surface area m2
Swpie
Material
Unit
Consumption per 1 m2
Consumption
on {total} m2
Price
per unit*
Value

Value of materials per 1m2 of wall

:
{get_calculation_per_meter} PLN

Value of materials per 1m2 of wall

: {get_calculation_per_meter} PLN

Total value of materials for the wall surface area

:
{get_total_calculation} PLN

Total value of materials for the wall surface area

: {get_total_calculation} PLN

The above material consumption standards are just estimates and do not include waste resulting from material installation. The calculation does not constitute a commercial offer within the meaning of Article 66 § 1 of the Civil Code.

* In order to calculate the wall construction cost, enter material unit prices.

Q1 - Double filling of plasterboard joints and connections with a structural joint filler (Norgips Start & Finish or Norgips Star), sealing a reinforcing tape, covering visible fasteners with a joint filler

Q2 - Includes the Q1 scope plus filling plasterboard joints with a finish joint filler (Norgips Extra Finish, Norgips Start & Finish or Norgips Finish) until a smooth transition of a joint into a plasterboard surface is achieved

Q3 - Includes the Q2 scope plus filling the entire partition element (joints and cardboard) with an approx. 1 mm thick layer of finish joint filler (Norgips Extra Finish, Norgips Start & Finish or Norgips Finish) to level the surface, close all pores and consolidate absorptivity of filled surfaces

Project information:
Additional comments:
Save the prepared calculation:
PDF calculator SDM - 2x12,5 GKB A + DFH2IRE/1x12,5 DFH2IRE/2xCW 50 2xW
XLS calculator SDM - 2x12,5 GKB A + DFH2IRE/1x12,5 DFH2IRE/2xCW 50 2xW

Download To file
Declaration of Performance Declaration of Performance No. Acoustic Super 12,5/N/2025 date: 13 Aug 2025 – DFH2IRE 12,5 - EN 520
Download To file
Declaration of Performance Declaration of Performance No. GKB A 12,5/N/2025 date: 13 Aug 2025 – A 12,5 - EN 520

Download To file
Technical sheet KT - Rawlplugs
Download To file
Technical sheet KT - Fleece tape 50 mm
Download To file
Technical sheet KT - NORGIPS Start & Finish
Download To file
Technical sheet KT - Sound insulating sealing tape
Download To file
Technical sheet KT - Paper tape 50 mm
Download To file
Technical sheet KT - NORGIPS Extra Finish
Download To file
Technical sheet KT - Rawlplugs, consumer packed
Download To file
Technical sheet KT - NORGIPS Finish MEGA
Download To file
Technical sheet KT - CW 50 PROFILE made of 0,6 mm sheet metal
Download To file
Technical sheet KT - UW 50 PROFILE made of 0,6 mm sheet metal
Download To file
Technical sheet KT - Sheet metal screws
Download To file
Technical sheet KT - Sheet metal screws consumer packed
Download To file
Technical sheet KT - UW 50 SUPER PROFILE made of 0.6 mm sheet metal (C3)
Download To file
Technical sheet KT - CW 50 SUPER PROFILE made of 0.6 mm sheet metal (C3)
Download To file
Technical sheet KT - CW 50 PROFILE made of 0,55 mm sheet metal
Download To file
Technical sheet KT - UW 50 PROFILE made of 0,55 mm sheet metal
Download To file
Technical sheet KT - Sheet metal screws on a strip 3,5 x 25 mm - EN
Download To file
Technical sheet KT - NORGIPS Finish
Download To file
Technical sheet KT - NORGIPS Start
Download To file
Technical sheet KT - NORGIPS S ACOUSTIC SUPER 12.5 mm type DFH2IRE
Download To file
Technical sheet KT - NORGIPS S GKB 12,5 mm type A

Download To file
Catalogues and leaflets NORGIPS solutions - Partition walls joints – assembly details

Download To file
Environmental Product Declaratio… EPD (Riga - LV) - Norgips GKB 12.5mm
NORGIPS partition wall system with a single-layer plasterboard cladding- step by step
NORGIPS Tips: Drywall Partition Wall in the Attic
Sheet metal screws on a strip 3,5 x 25 mm New
Phosphate-coated sheet metal screws for affixing plasterboards to steel profiles
Sheet metal screws on a strip 3,5 x 35 mm New
Phosphate-coated sheet metal screws for affixing plasterboards to steel profiles
Sheet metal screws 3.5 x 25 mm
Phosphate-coated sheet metal screws for affixing plasterboards to steel profiles
Sheet metal screws 3.5 x 35 mm
Phosphate-coated sheet metal screws for affixing plasterboards to steel profiles
Sheet metal screws consumer packed 3.5 x 25 mm
Phosphate-coated sheet metal screws for affixing plasterboards to steel profiles
Sheet metal screws consumer packed 3.5 x 35 mm
Phosphate-coated sheet metal screws for affixing plasterboards to steel profiles
Rawlplugs 6 x 40 mm
Rawlplugs for fixing profiles
Rawlplugs, consumer packed 6 x 40 mm
Rawlplugs for fixing profiles
Fleece tape 50 mm
Fleece tape for reinforcing plasterboard joints
Paper tape 50 mm
Paper tape for reinforcing plasterboard joints
Sound insulating sealing tape 50 mm
Self-adhesive tape for perimeter sealing in plasterboard lining systems
NORGIPS Finish MEGA New
Ready-mixed finishing compound for smooth pointing and skimming of indoor mineral substra…
NORGIPS Start & Finish
Ready-mixed dual-purpose filler and finishing compound for grouting plasterboard joints a…
NORGIPS Extra Finish
Ready-mixed finishing compound for grouting plasterboard joints and thin-layer levelling …
NORGIPS Start
Gypsum filler for grouting plasterboard joints
NORGIPS Finish
Gypsum filler for grouting plasterboard joints and thin-layer levelling of mineral substr…
Send a message

We believe that personal data security is a very important issue.
As a result, we provide you with information about the personal data we process. The personal data Controller is Norgips Sp. z o.o. with its registered office /02-255/ Warszawa, ul. Krakowiaków 50. Your data will be processed for the purpose of handling the inquiry you sent to us.
Find more in our Privacy Policy.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Rafał Kaczmarczyk
Deputy Technical Support Manager
Document file
Document file
close

A selection of downloads and material consumption calculations from our website can be included in the document folder.

Click

'To folder' on any document or calculation.

With the document folder you can easily prepare documentation for your investment including:

  • technical documentation of products and solutions
  • material consumption calculations
  • summary product list
  • title sheet with investment metric
Download ZIP Download ZIP
Download PDF Download PDF
Send to @ Send to @
 Clear the file
Close
up